Solenoid Valve


Solenoid Valve

Rain Bird DV/DVF Series



Plastic Residential Irrigation Valves

 

All of our valves work with any standard sprinkler timer.Rain Bird manufactures only the highest quality valves. Use DV/DVF series valves in locations where the use of a separate pressure vacuum breaker (PVB

  • Pressure: 15 to 150 psi (1,0 to 10,4 bar)
  • 075-DV Flow: 0.2 to 22 GPM 

     

    (0,05 to 5,0 m3/h; 0,01 to 1,39 l/s). For flows below 3 GPM (0,75 m3/h; 0,21 l/s) or any Xerigation® application, use RBY-075-200MX Filter installed upstream.
  • 100-DV Flow): 0.2 to 40 GPM (0,05 to 9,08 m3/h; 0,01 to 2,52 l/s). For flows below 3 GPM (0,75 m3/h; 0,21 l/s) or any Xerigation® application, use RBY-100-200MX Filter installed upstream.
  • 100-DVF Flow (non-union): 0.2 to 40 gpm (0,75 m3/h; 0,21 l/s); for flows below 3 gpm or any Xerigation application, use RBY-100-200MX Filter installed upstream.
  • Temperature: Up to 110° F (43° C)
  • Ambient air temperature: Up to 125° F (52° C)
  • 24 VAC 50/60 Hz (cycles per second) solenoid power requirement:
  • 0.30 A (7.2 VA) inrush current; 0.23 A (5.5 VA) holding current
  •  

Hunter PGV Valve Series

DIMENSIONS
• 1" Globe and Male x Male: 5" H x 4 1/2" L x 2 1/2" W 
(13 cm H x 11 cm L x 6 cm W)
• 1" Male x Barb: 5" H x 5 1/2" L x 2 1/2" W 
(13 cm H x 14 cm L x 6 cm W)
• 1" Angle: 5 1/2" H x 3 1/2" L x 2 3/4" W 
(14 cm H x 9 cm L x 7 cm W)
• 1 1/2" Globe/Angle: 7 1/2" H x 5 3/4" L x 4 1/2" W 
(19 cm H x 15 cm L x 11 cm W)
• 2" Globe/Angle: 8" H x 6 3/4" L x 5 1/4" W 
(20 cm H x 17 cm L x 13 cm W)

OPERATING SPECIFICATIONS
• Flow: .2 to 120 GPM (0.04 to 27.2 m3/hr; 0.7 to 454.2 l/min)
• Pressure: 20 to 150 PSI (1.4 to 10.3 bars; 138 to 1034 kPa)
• Ambient temperature: up to 150˚F (66˚C)
• Heavy-duty solenoid: 24VAC, 370mA inrush current, 
190mA holding current, 60 cycles; 475mA inrush current, 
230mA holding current, 50 cycles

OPTIONS AVAILABLE
• Accu-Set™ pressure regulator
• Reclaimed water identification handle PGV-101 models (part # 269205) 
for PGV-151/201 models (part# 412705)
• DC latching solenoid (part # 458200)
• Solenoid conduit cover (part # 464322)
• Drip Irrigation Valve Kit (part # PCZ10125 or PCZ10140)


SPECIFICATION GUIDE
EXAMPLE: PGV - 100G - S - AS
MODEL
PGV
FEATURES
100G = 1" Globe Valve, no Flow Control
101G = 1" Globe Valve, with Flow Control
100A = 1" Angle Valve, no Flow Control
101A = 1" Angle Valve, with Flow Control
100MB = 1" Globe Valve, no Flow Control, Male Thread x 1" Barb
100MB125 = 1" Globe Valve, no Flow Control, Male Thread x 1 1/4" Barb
101MB = 1" Globe Valve, with Flow Control, Male Thread x Barb
101MB125 = 1" Globe Valve, with Flow Control, Male Thread x 1 1/4" Barb
100MM = 1" Globe Valve, no Flow Control, Male x Male
101MM = 1" Globe Valve, with Flow Control, Male x Male
151 = 1 1/2" Globe/Angle Valve, with Flow Control
201 = 2" Globe/Angle Valve, with Flow Control
OPTIONS FACTORY INSTALLED
S = Slip x Slip (1" Models Only)
B = BSP Threads
DC = DC Latching Solenoid
LS = Less Solenoid
OPTIONS USER INSTALLED
AS = Accu-Set™ Pressure Regulator
(1 1/2" and 2" Models Only)
R = Reclaimed Water Identification Handle or Tag
CC = Conduit Cover
     

   

Saat/Tarih